Search results for " contact lenses"

showing 10 items of 11 documents

Accommodative response in various design soft contact lens wearers

2021

The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22â28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design f…

Accommodative responsegenetic structuresbusiness.industrynear additionScienceQGeneral Engineeringaccommodative lageye diseasesmultifocal contact lensesContact lensOptometryMedicinesense organsbusinessmyopia control.Proceedings of the Estonian Academy of Sciences
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes

2018

Objective: To evaluate corneal biomechanical parameters wearing corneoscleral contact lenses (CScL) in patients with irregular corneas after laser in situ keratomileusis (LASIK). Methods: Data from patients fitted with CScL because of corneal surface irregularities after complicated LASIK surgery were selected by two eye clinics. Previously and after 1 year of CScL fitting, corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and central corneal thickness were evaluated. In addition, visual acuity, subjective comfort, and wearing time CScL were reported. Results: The study comprised 27 eyes. Statistically significant differences were fo…

AdultMalemedicine.medical_specialtyIntraocular pressureCorneal Wavefront AberrationVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCorneal resistance factorKeratomileusisLASIKCorneaCorneal hysteresis03 medical and health sciences0302 clinical medicineOphthalmologyMyopiamedicineHumansIn patientCorneal surfaceRefractive surgeryIntraocular PressureRetrospective Studiesbusiness.industryLASIKCorneal hysteresisContact Lenses Hydrophiliceye diseasesBiomechanical PhenomenaScleraOphthalmologymedicine.anatomical_structureCorneoscleral contact lensesPatient Satisfaction030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessSclera030217 neurology & neurosurgery
researchProduct

Efficacy and safety study of an eyelid gel after repeated nocturnal application in healthy contact lens users and non-users

2020

Purpose: To evaluate skin biocompatibility of a nighttime hydrating eyelid gel and possible ocular surface effects in contact lens users (CLU) and non-contact lens users (NCLU). The formulation is registered as a medical device as Tridocosahexaenoine-AOX® (TDHA-AOX) (a concentrated DHA triglyceride), containing also hyaluronic acid (HA). Methods: A prospective, randomized, masked clinical trial was performed with 62 participants of both sexes, aged 20–70 years, split into: (1) CLU (n = 30) and (2) NCLU (n = 32). All participants were instructed to apply a single dose of the moisturizing gel (containing TDHA-AOX and HA) nightly to the upper and inner eyelids of their right eye (RE) only, and…

DHA docosahexaenoic acidNon usersFBUT fluorescein break-up timeALA alpha linolenic acidTDAH-AOX tridocosahexaenoin-antioxidantNCLU non contact lens users0302 clinical medicineLC PUFAs long chain polyunsaturated fatty acidsMedicineCL contact lensesOS ocular surfaceHA hyaluronic acidOSDI ocular surface disease indexDE dry eyeCLU contact lens usersCLDEQ contact lens dry eye questionnaireVEGF vascular endothelial growth factorDocosahexaenoic acidBMC biomicroscopymedicine.anatomical_structureMedicamentosCytokinesOftalmologíaOriginal ArticleBCVA best corrected visual acuitymedicine.medical_specialtyOcular surface dysfunctionCorneal stainingContact LensesHyaluronic acidRE right eyeDEs dry eye syndrome03 medical and health sciencesOphthalmologyHumansAdverse effectbusiness.industryEyelidsEPA eicosapentaenoic acidAnatomía ocularIOP intraocular pressureeye diseasesClinical trialContact lensMOISTURIZING GEL030221 ophthalmology & optometryTearsLE left eyeEyelidsense organsbusiness030217 neurology & neurosurgeryOptometry
researchProduct

Individuālu mīksto kontaktlēcu pielietojums acs aberāciju kompensācijai

2017

Darbs uzrakstīts angļu valodā uz 63 lapām. Tas satur 46 attēlus, 1 tabulu un 53 atsauces uz literatūras avotiem. Mērķis. Novērtēt agstāko kārtu aberāciju (HOA) ietekmi uz redzes funkcijām un acs optisko kvalitāti FOOT kontaktlēcu (KL) nēsātājiem. Metodes. Tika izmērīts redzes asums gadījumos (RA), kad acī ievietotas FOOT KL un parastās gāzu caurlaidīgās KL. Tika izmērītas visas aberācijas (TA) un HOA gadījumā, kad ievietotas abu veidu lēcas. Rezultāti. FOOT KL gadījumā RA bija tāds pats kā parasto KL gadījumā, vai augstāks (p<.01). FOOT KL gadījumā TA un HOA līmenis bija tāds pats kā parasto KL gadījumā, vai mazāks (p-value < .01). Secinājumi. FOOT KL sniedz augstāku RA nekā parastās KL un …

High order aberrations.FOOT CLsOptometrijaWavefront-Optimized contact lenses
researchProduct

Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manu…

2007

PURPOSE: The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. METHODS: Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range…

Materials scienceSiliconesRefractive indexBiomedical EngineeringAnalytical chemistryBiocompatible Materials02 engineering and technologyBiomaterials03 medical and health sciences0302 clinical medicineRefractometerHumansBrix sucrose scaleBrix scaleCLR 12-70Water contentSoft contact lenseschemistry.chemical_classificationScience & TechnologyEquilibrium water contentWaterHydrogelsAtago N2EsucrosePolymerSilicone hydrogelconventional soft contact lensesContact Lenses Hydrophilic021001 nanoscience & nanotechnologyContact lensRefractometrychemistrySelf-healing hydrogelsSilicone hydrogel030221 ophthalmology & optometry0210 nano-technologyRefractometryRefractive indexJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy

2006

The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …

Materials scienceSiloxanesScanning electron microscopeSurface PropertiesBiomedical Engineering02 engineering and technologyContact lens materialsHydrogel Polyethylene Glycol Dimethacrylatelaw.inventionBiomaterials03 medical and health sciences0302 clinical medicineOpticssilicone-hydrogellawMicroscopyMaterials TestingHumansCryo-scanning electron microscopyComposite materialchemistry.chemical_classificationScience & Technologybusiness.industryCryoelectron MicroscopyCryoSEM microscopyPolymerLiquid nitrogenpolymer surface021001 nanoscience & nanotechnologyContact Lenses HydrophilicSiloxane-hydrogel contact lensescryoSEMLens (optics)Contact lenschemistry030221 ophthalmology & optometryUltrastructuremicroscopysiloxane-hydrogels0210 nano-technologybusiness
researchProduct

Microscopic observation of unworn siloxane-hydrogel soft contact lenses by atomic force microscopy

2006

In the present study, samples of lotrafilcon A, balafilcon A, and galyfilcon A contact lenses were observed by atomic force microscopy (AFM) in tapping mode at areas ranging from 0.25 to 400 m2. Mean roughness (Ra), root-mean-square roughness (Rms) and maximum roughness (Rmax) in nanometers were obtained for the three lens materials at different magnifications. The three contact lenses showed significantly different surface topography. However, roughness values were dependent of the surface area to be analyzed. For a 1 m2 area, statistics revealed a significantly more irregular surface of balafilcon A (Ra = 6.44 nm; Rms = 8.30 nm; Rmax = 96.82 nm) compared with lotrafilcon A (Ra = 2.40 nm; …

Materials scienceSiloxanesSurface PropertiesBiomedical EngineeringNanotechnology02 engineering and technologyMicroscopy Atomic ForceHydrogel Polyethylene Glycol DimethacrylateBiomaterialsAtomic force microscopy03 medical and health scienceschemistry.chemical_compoundSurface roughness0302 clinical medicineMaterials TestingSurface roughnessHumansScience & TechnologyAtomic force microscopyContact Lenses Hydrophilic021001 nanoscience & nanotechnologySiloxane-hydrogel contact lenses3. Good healthMicroscopic observationchemistrySiloxaneWettability030221 ophthalmology & optometry0210 nano-technologyJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Redzes funkciju izvērtējums pacientiem agrīnā presbiopijas vecumā ar vienas dienas multifokālajām kontaktlēcām

2017

Bakalaura darbs uzrakstīts uz 27 lapaspusēm, satur 18 zīmējumus, 1 tabulu un 20 literatūras avotus. Darba mērķis ir novērtēt redzes asumu un kontrasta jūtību fotopiskos un mezopiskos apstākļos pacientiem, koriģētiem ar brillēm un vienas dienas multifokālajām kontaktlēcām. Mūsu pētījumi parādīja, ka fotopiskos apstākļos pacientiem pēc korekcijas ar multifokālajām kontaktlēcām redzes asums vidēji samazinājās par 0,02 logMAR vienībām. Mezopiskos krēslas apstākļos pacientiem koriģētiem ar multifokālajām kontaktlēcām redzes asuma samazinājums vidēji bija 0.05 logMAR vienības. Atšķirības redzes asumā ir statistiski nozīmīgas. Kontrasta jūtības vidējie lielumi pēc kontaktlēcu uzlikšanas vidēji sam…

contrast sensitivityphotopic conditionpresbyopia correctionmesopic conditionOptometrijamultifocal contact lenses
researchProduct

Ahromatopsijas izpausmju korekcija ar krāsainām kontaktlēcām

2017

MĒRĶIS: Novērtēt filtru kontaktlēcu (KL) pielietojumu ahromatopsijas simptomu korekcijai. METODE: Pētījumā piedalījās 8 dalībnieki (6 sievietes un 2 vīrieši) vecumā no 8 mēnešiem līdz 25 gadiem, periodā no 2012. līdz 2016.gadam. Pēc oftalmoloģiskās pārbaudes un ahromatopsijas noteikšanas, tika veikta speciālās krāsainās KL pielaikošanas procedūra. Pacientu atbildes tika noteiktas ar anketas palīdzību un noteikts apžilbšanas laiks ar un bez piedāvātām KL. SECINĀJUMI: filtru KL samazināja fotofobiju; apžilbšanas laiks kļuvis salīdzināms ar normālā redzes gadījumu; dalībnieki atzinīgi novērtē psiholoģiskos un sociālos ieguvumus ar izrakstītām filtru KL.

filtered contact lensesphotophobiaFizikaglareachromatopsialight
researchProduct